Your Funiki air conditioner is operating abnormally, accompanied by strange symbols such as F1, F2, E4, ... appearing on the screen? Don't worry too much! What you need to do now is look up the error code table of Funiki air conditioners below to find the cause and the most accurate solution.
Table of Contents
Funiki air conditioner error code |
Model |
Error name |
How to fix |
E01 |
FC45M, FH45M |
10 Kohm air sensor error. Air conditioner does not work, phenomenon similar to power loss. |
Contact technical staff for support. |
E02 |
FC45D, FH45D |
Indoor unit high temperature protection sensor is broken (compressor not running). Need to check sensor and gas. |
Check sensor and gas. |
E02 |
FC, FH45 |
Only indoor fan running, low pressure valve error, high pressure, phase deviation. |
Contact technical staff for support. |
E02 |
FC45M, FH45M |
10 kohm sensor error. |
Contact technical staff for support. |
E03 |
FC45D, FH45D |
Indoor unit anti-freeze protection sensor error (block not running). Carefully check sensor, check gas. |
Check gas and sensor. |
E03 |
FC45M, FH45M |
10 Kohm outdoor sensor error. Can be reconnected and the machine will still run normally. |
The circuit can be short-circuited. |
E04 |
FC45D, FH45D |
Gas loss protection error, only the evaporator fan is running. Fix by leaking and refilling gas. |
Can leak and refill gas for air conditioner. |
E05 |
FC, FH45 |
Air sensor error, coil sensor error (run for 45 minutes, stop for 10 minutes). |
Contact technical staff for support. |
E06 |
FC, FH45 |
Evaporator sensor error (on for 45 minutes, off for 10 minutes). Check 10 Kohm probe and connector. |
Check high pressure, low pressure due to cable blockage, check gas for excess or shortage. |
E06 |
FC45M, FH45M |
Wrong phase, phase protector failure, check high pressure, low pressure due to cable blockage, excess gas or lack of gas. |
Check the 10 kOhm probe and sensor connector. |
E07 |
FC, FH45 |
Condenser sensor error. Fix by checking the 10 Kohm probe and the connector, the probe can be short-circuited at the control board. |
Check the 10 kOhm probe and the air conditioner connector; fix by short-circuiting the probe on the control board. |
E09 |
FC, FH45 |
Only the evaporator fan is running, possibly due to lack of gas or incorrect evaporator sensor value. |
Contact technical staff for support. |
E1 |
FC, FH24M |
Air sensor error. |
Contact technical staff for support. |
E2 |
FC24M, FH24M, FC27M, FH27M |
Sensor error. |
Contact technical staff for support. |
E3 |
FC45D, FH45D |
Evaporator sensor error. |
Contact technical staff for support. |
E4 |
Squirrel cage fan error does not run due to jamming or damage. |
Contact technical staff for support. |
|
E5 |
Air sensor broken or shorted; connector loose or damaged. |
Contact technical staff for support. |
|
E5 |
FC24, FH24, FC27, FH27 |
Wrong sensor or low gas system. |
Contact technical staff for support. |
E5 |
FC45D, FH45D |
Air sensor error (on 45 minutes, off 10 minutes). |
Contact technical staff for support. |
E6 |
Sensor error is broken or short-circuited, plug is loose or damaged. |
Contact technical staff for support. |
|
E6 |
FC24, FH24, FC27, FH27 |
Air sensor error (on 45 minutes, off 10 minutes). |
Contact technical staff for support. |
E6 |
FC45D, FH45D |
Evaporator sensor error (on for 45 minutes, off for 10 minutes). |
Replace the evaporator sensor with the correct value. |
E7 |
FC24, FH24, FC27, FH27 |
Error in sensor, wire, plug (on for 45 minutes, off for 10 minutes). |
Contact technical staff for support. |
E9 |
Gas shortage error; voltage voltage; sensor error value. |
Contact technical staff for support. |
|
FC |
Reset button is stuck |
Check the Reset button and remote control. Using the remote control to increase or decrease the air conditioner temperature will fix the problem. |
|
FF4 |
FC, FH27G |
High temperature protection sensor error; need to check connector, sensor and gas. |
Check and fix the plug, sensor or gas. |
FF7 |
FC, FH27G |
Air sensor error, sensor resistance 5 Kohm. |
Contact technical staff for support. |
FF8 |
FC, FH27G |
Error in the sensor, 5 Kohm sensor. Need to check the gas and plug. |
Check plug and gas. |
F4 |
High temperature protection sensor error, machine stops all operations. |
Check the plug, sensor and gas. |
|
EC |
New Funiki air conditioners after 2019 |
The engine block is overheating, out of gas or the circuit board is damaged. |
Check engine block, internal gas or replace circuit board. |
E3 |
Error in the indoor unit's anti-freeze protection sensor (block stops working). |
Check the sensor and gas level in the machine. |
|
E4 |
Fan or motherboard error. |
Check the fan and circuit board to see if they can be reconnected or need to be replaced. |
>> Share :
Thus, we have provided you with a detailed table of Funiki air conditioner error codes. Use it to determine the "disease" your device is suffering from and find a timely solution.
In the errors in the table above, E4 and E6 are the most common codes.
The evaporator fan (evaporator squirrel cage fan) is not working or does not send pulses to the microprocessor. To fix this problem, you first need to check if the fan is working properly. If the fan is still working properly, the motherboard is most likely damaged. If the fan does not run, it is most likely due to a power supply or a broken evaporator fan.
This is an evaporator sensor error. If the Funiki air conditioner reports error E6, you should replace the evaporator sensor with the correct type and value.
Error E3 on Funiki air conditioner shows that the anti-frost protection sensor on the evaporator is broken, usually appearing after about 3-5 minutes right after you start the air conditioner. At that time, the word E3 appears right on the LED screen and the evaporator fan stops working.
The cause of error E3 on Funiki air conditioner is due to damaged components after a period of use or the air conditioner is low/out of gas.
How to fix error E3 Funiki air conditioner:
Step 1: Remove the Funiki air conditioner's mask cover with a screwdriver to check if the fan's power cord is broken.
Step 2: Check if the evaporator fan capacitor is damaged by using an electric meter. If the evaporator fan capacitor is damaged, replace it with a new capacitor of the same value.
Step 3: Check if the evaporator fan is broken, if broken, replace the fan.
Step 4: After checking all the above causes but the Funiki air conditioner still displays error E3, the air conditioner is out of gas or the control circuit is broken.
Step 5: Check the air conditioner gas by turning on the air conditioner at the temperature you want to set, check if the correct cooling mode is selected or not. If the air conditioner does not emit cool air, the air conditioner may be out of gas.
Step 6: Check to see if the condenser fan is spinning and if there is heat coming out of the condenser when the air conditioner is running?
Step 7: Check the air conditioner sensor. You should only do this yourself if you have expertise.
How to fix error E3 Funiki air conditioner is quite complicated and difficult to solve. To avoid more serious damage, please contact the warranty or experienced and professional technical teams for support.
Hopefully our sharing about Funiki air conditioner error codes and how to fix some common problems will help you more or less. Visit META.vn if you need more advice about Funiki air conditioners.
>>> See more :
Building muscle takes time and the right training, but its something anyone can do. Heres how to build muscle, according to experts.
In addition to regular exercise and not smoking, diet is one of the best ways to protect your heart. Here are the best diets for heart health.
The third trimester is often the most difficult time to sleep during pregnancy. Here are some ways to treat insomnia in the third trimester.
There are many ways to lose weight without changing anything in your diet. Here are some scientifically proven automatic weight loss or calorie-burning methods that anyone can use.
Apple has introduced iOS 26 – a major update with a brand new frosted glass design, smarter experiences, and improvements to familiar apps.
Yoga can provide many health benefits, including better sleep. Because yoga can be relaxing and restorative, its a great way to beat insomnia after a busy day.
The flower of the other shore is a unique flower, carrying many unique meanings. So what is the flower of the other shore, is the flower of the other shore real, what is the meaning and legend of the flower of the other shore?
Craving for snacks but afraid of gaining weight? Dont worry, lets explore together many types of weight loss snacks that are high in fiber, low in calories without making you try to starve yourself.
Prioritizing a consistent sleep schedule and evening routine can help improve the quality of your sleep. Heres what you need to know to stop tossing and turning at night.
Adding a printer to Windows 10 is simple, although the process for wired devices will be different than for wireless devices.
Diet is important to our health. Yet most of our meals are lacking in these six important nutrients.
You want to have a beautiful, shiny, healthy nail quickly. The simple tips for beautiful nails below will be useful for you.
Students need a specific type of laptop for their studies. It should not only be powerful enough to perform well in their chosen major, but also compact and light enough to carry around all day.
Birth defects are something no one wants. Although they cannot be completely prevented, you can take the following steps to reduce the risk of birth defects in your baby.
As you know, RAM is a very important hardware part in a computer, acting as memory to process data and is the factor that determines the speed of a laptop or PC. In the article below, WebTech360 will introduce you to some ways to check for RAM errors using software on Windows.